Opened 3 years ago

Closed 3 years ago

#1001 closed defect (fixed)

MSConvert: Does not work for certain folder and filenames

Reported by: sena Owned by: sena
Priority: normal Milestone: GRITS - 1.2 SR1
Component: MS data management Version: GRITS 1.2.x
Severity: major Keywords:
Cc:

Description

From Mindy: "I am testing and I tried to convert RAW instrument files that I uploaded to grits using the convert feature and got this error message"

Attachments (1)

psacqegv.png (153.0 KB) - added by sena 3 years ago.

Download all attachments as: .zip

Change History (4)

Changed 3 years ago by sena

Attachment: psacqegv.png added

comment:1 Changed 3 years ago by sena

Component: GRITS coreMS data management

comment:2 Changed 3 years ago by sena

Resolution: fixed
Status: assignedreview

The error was due to the spaces and special characters (%) in the filename and also in the workspace folder name. I've changed the way the command line is created to handle escaping those special characters in the filenames.

comment:3 Changed 3 years ago by sena

Status: reviewclosed
Note: See TracTickets for help on using tickets.